A specification sheet for methylene blue, CAS 61-73-4, packs a lot of vocabulary into a single page, and most acceptance mistakes in the stockroom come from misreading one of those entries rather than from the material itself. The compound is a cationic phenothiazine dye, catalogued as methylthionine chloride, with the linear formula C16H18ClN3S and a molar mass of 319.85 g/mol for the anhydrous salt. The glossary below walks through the terms that appear on almost every supplier document for this material.

Methylthionine chloride
The systematic name of the catalogued salt. It names the chloride of the coloured cation, which is why the tabulated molar mass covers the counter-ion as well as the chromophore.
Linear formula
Written as C16H18ClN3S for the anhydrous salt. Hydrated grades exist and carry a higher figure, so the container label rather than a textbook value governs any weighing calculation.
Dye content
The declared fraction of the weighed powder that corresponds to the chromophore itself. Synthetic dyes are isolated by salting out, so inorganic salts and bound water make up the remainder, and molar concentrations must be corrected for this figure.
Absorption maximum
A dilute aqueous solution of the monomeric form peaks near 664 nm in the visible range. This band is the quickest identity marker available at the bench and is normally recorded during incoming inspection.
Dimer band
Above roughly 7 × 10-6 mol/L the solution starts to show a second feature between 570 and 600 nm as dimers form. Its growth signals that the working solution has moved out of the range where absorbance stays linear with concentration.
Molar extinction coefficient
Published figures at 664 nm scatter roughly between 7.4 × 104 and 9.5 × 104 L mol-1 cm-1. The spread reflects differing ionic strength, pH and dye-content corrections, which is why quantitative work relies on an in-house calibration curve.
Leuco form
The reduced, colourless species obtained in the presence of reducing agents, which reverts to the coloured cation on exposure to air. Its formation explains why stock solutions are kept in amber glass and why an unexpectedly pale solution is a handling flag, not a labelling error.
Loss on drying
The mass fraction removed under defined drying conditions, dominated by bound and adsorbed water. Hygroscopic grades drift upward once the container has been opened in a humid room.
Insoluble matter
The residue left after dissolving a defined portion in water. A raised value points to filtration problems at the manufacturing stage and shows up as haze in freshly prepared working solutions.
Grade designation
Phrases such as for microscopy, for microbiology or histological grade encode which impurity limits were tightened. They are not interchangeable, and substituting one grade for another silently changes the limits a laboratory has qualified against.

How the terms interact in practice

Dye content, loss on drying and insoluble matter are not independent numbers. A container stored badly gains water, which raises loss on drying and lowers the true chromophore fraction of every subsequent weighing, even though the certificate of analysis still shows the value measured at release. Recording the opening date on the container and repeating the spectral check after long storage keeps the paperwork aligned with the material actually on the shelf.

Where the numbers usually go wrong

Three recurring problems account for most disagreements between two laboratories measuring the same container. The first is weighing a hydrated grade against an anhydrous molar mass, which shifts every derived concentration by a fixed factor. The second is skipping the dye-content correction, which biases results in the same direction and is easy to miss because the arithmetic still looks tidy. The third is preparing a stock solution concentrated enough that dimers dominate the spectrum, then diluting it and assuming linearity held throughout the range. Zobacz również odczynnik w opakowaniu gramowym: Modafinil (CAS 68693-11-8) — certyfikat analizy od.

None of these is caught by a purity figure alone, and none of them shows up in a chromatogram. They are caught by preparing a calibration series from an independently weighed portion and confirming that absorbance tracks concentration across the whole working range before any sample is measured against that curve.

What to file with the batch

A retained certificate of analysis, the batch number, the opening date and a locally recorded spectrum of the first working solution form a compact record that allows any later measurement to be traced. Keeping a small retention sample from the same container closes the loop, because it lets a questionable result be re-examined against the material that produced it rather than against a fresh order. Dye chemistry is forgiving of small handling errors and unforgiving of undocumented ones. Zobacz również odczynnik w opakowaniu gramowym: Sildenafil / Cytrynian Sildenafilu / VIAGRA / Czys.

Zobacz też w katalogu

Piśmiennictwo

Badania na zwierzętach i in vitro indeksowane w bazie PubMed; strona nie zawiera wskazówek dotyczących stosowania u ludzi.

  • Wiklund L Neuroprotection by Methylene Blue in Cerebral Global Ischemic Injury Induced Blood-Brain Barrier Disruption and Brain Pathology: A Review 2016, CNS & neurological disorders drug targets. PMID 27633785
  • Rojas JC Neurometabolic mechanisms for memory enhancement and neuroprotection of methylene blue 2012, Progress in neurobiology. PMID 22067440
  • Batista-Filho MM Role of Methylene Blue in Trauma Neuroprotection and Neuropsychiatric Diseases 2016, CNS & neurological disorders drug targets. PMID 27450870
  • Tucker D From Mitochondrial Function to Neuroprotection-an Emerging Role for Methylene Blue 2018, Molecular neurobiology. PMID 28840449

Przeznaczenie materiału. Materiał nie jest przeznaczony do użycia przez ludzi. Materiał nie jest produktem weterynaryjnym. Jest to wysokiej czystości produkt laboratoryjny do prac badawczych z użyciem HPLC i GC-MS. Poza kategorią produktów leczniczych i spożywczych.